The incident occurred in a catalytic reforming unit. At 13:41, a leak occurred at the 90° elbow of a pressure pipe containing a mixture of hydrogen and naphtha. This pipe was located between the pre…
The event started at the effluent pipe of one of the hydro-cracking reactors, which broke and released a mixture of hydrogen, light gases (methane, butane), light gasoline; heavy gasoline; gas oil.…
The boat was a 6. 5 m semi-rigid electric-powered inflatable canoe, mainly used for greeting and directing pleasure boaters in harbour. It exploded without a flame shortly when an employee of the…
The balloon had a 3. 5m external diameter envelope made of anti-tear fabric (same techniques used in full sized balloons of the same company). The inner balloon was a meteorological balloon made of…
The accident happened in an anhydrous ammonia plant, commissioned in March 1977. Hydrogen accumulated inside a Benfield solution (hot potassium) storage tank and was ignited by a static charge, which…
This incident occurred at the hydrogen production and storage unit of (probably) a power plant using hydrogen as a coolant of the turbine-generator system. Hydrogen was produced probably by water…
A serious chemical accident occurred at chemical industry producing olephins and phenols. The accident resulted in injuries to several workers and extensive damage to the plant, as well as minor…
A section of effluent piping ruptured on the hydrocracker reactor of a refinery. A mixture of light gases (methane, butane), light and heavy gasoline, gas oil and hydrogen was released from the pipe…
The incident occurred on two hydrogen compressor units installed on the roof of a four-story building. The Great East Japan Earthquake caused the rupture of the flexible piping and the outlet piping…
The accident occurred in a disposal storage for contaminated waste, consisting in a 65-metre shaft flooded with seawater. At the origin of the explosion was the reaction with water of at least two…
Hydrogen gas cylinders exploded at the same time in three industrial locations, when the opening valve was opened. The overpressure generated by the explosion caused the walls of the hydrogen…
The last flight of the Space Shuttle Challenger ended 73 seconds after the launch in an explosive burn of hydrogen and oxygen propellants that destroyed the External Tank and exposed the Orbiter to…

A compressed hydrogen container was being filled at a refuelling station. The container was belonging to trailer and consisted in a bundle of tubes connected via piping to a manifold and filling…

An explosion occurred in a nitrogen wash cold box (outside the equipment) after a several day cold shutdown followed by a derime with nitrogen. It is assumed that ice may have split tubes…

The incident occurred at the hydrofining unit, refining a mixture of petroleum and diesel into Euro 3 and Euro 4 diesel. A pump feeding the reactor with the process mixture failed. Following the…

A hydrogen-air explosion occurred outside a hydrogen compressor. Gaseous hydrogen was released from the vent stack due to a premature activation of a relief valve. The flammable atmosphere ignited…

An explosion occurred at a hydrogen compressor of a polysilicon plant. The head of the compressor was blown off and the released hydrogen exploded causing extensive damage to the building and to…

The incident involved an hydrogen-on-demand unit (HOD), which was installed inside an environmental test chamber used for reliability tests. An employee was troubleshooting the chamber, assessing the…

While preparations were being made for a LH2 turbopump test, an explosion occurred above the test cell. Major damage was caused throughout the test facility. A short duration fire caused minor…

A special test was being executed to evaluate a high-pressure fuel turbo-pump lift-off seal. During the test, an open-air explosion took place on the test stand. There were no injuries, but non…