HIAD Causes: System Design Error


During initial resting at a liquid hydrogen bubble chamber facility, an explosion occurred shortly after opening a high pressure hydroger line. The explosion was assumed to have taken place in the…

The event occurred at one of the unit producing iron powder, consisting of a furnace with a running belt for the powder, kept under hydrogen atmosphere to reduce and purify the metal. The hydrogen…
The incident occurred at the hydro-dealkylation (HDA) plant of an aromatics manufacturer. The affected component was a heat exchanger part of the hydrogen purification system. This part failed…
A syngas leak (hydrogen + methane) occurred at exit of the ammonia production reactor and led to an explosion followed by a fire. The start point of the sequence of events was the syngas at the…
The explosion occurred in a benzene production unit (Litol process), which was being restarted following a scheduled shutdown for maintenance. About 30 kilograms of hydrogen gas were relesed into a…
The event occurred at an ethylene production plant. The plant was shutdown at the time as the supply of compressed air to the gauges had inadvertently been switched off. This failure of the air…
The incident at a bio-fuels research laboratory occurred when a visiting research fellow was transferring hydrogen, oxygen and carbon dioxide from compressed gas cylinders into a low-pressure mixing…
A violent explosion occurred at a blast furnace. The explosion occurred while the blast furnace was being cleaned at the end of casting. For this purpose, worker poured the contents of a casting…
SUMMARY The explosion occurred in a catalyst regenerator of the catalytic cracking unit in a fluidized bed during a technical shutdown. A few seconds later, a second explosion is perceived, it is the…

[Note of the event validator: according to the sources, hydrogen as combustible gas does not seems to have plaid part in this incident. However, it is more plausible that hydrogen, as the main…

This incident occurred at a chlorine production plant. A number of minor explosions occurred in the interrupter pot on a chlorine cell of the electrolyser. No injuries or damage were reported. No…

The incident occurred at a dispenser of a hydrogen refuelling station (HRS). The HRS employee had just terminated the filling of a fuel cell vehicle (FHV) and was depressurising the filling hose,…

On a cold morning, the gasoil hydro-treatment unit was being brought back on line after being out of service to repair a governor problem on the recycle gas compressor. Several upset trips had…
A reactor of a wide-range hydrocracking unit being operated by computer at 2500 psi (170 bar) failed explosively due to localised heating. Resulting explosion caused injuries and widespread damage to…
Five workers were in the process of trouble shooting a hydrogen compressor. No actual work was in process, but the compressor had still hydrogen in the lines. The three were only listening for…
An explosion took place at a research facility of a university, due to an accidental release of hydrogen. Hydrogen gas was used in research reactors to deposit amorphous silicon thin films. The…
The event occurred in the steam condensing line of the residual heat removal system the nuclear reactor. Radiolysis generated hydrogen and oxygen, which then accumulated in high concentration in the…
An explosion occurred inside a pipe of a boiling water nuclear power reactor. The pipe was part of a core spray system, which was providing extra cooling when shutting down the reactor. The system…
At a rubber factory, an explosion occurred inside a lubricant container filled with 18 tonnes of tri-(nonylphenyl) phosphate (TNPP or TNPA). This tank was typically stirred and maintained at 45°C.…

The DC power system was serving as back-up power and was based on a battery storage system. It had been taken off-line to be replaced with a more modern system. After its replacement, at the…