HIAD Causes: System Design Error


An explosion occurred inside the hydrogen washing tower of a chlorine production plant. The explosion was preceded by an abrupt reduction in the electrolysis flow due to a rectifier malfunction. The…

During preparation of a spacecraft LH2 tank in an environmental test chamber, a liquid hydrogen fire occurred in the chamber. The tank was being "topped off" at the time. Damage was…

The event occurred on vent stack of an ammonia synthesis unit. The release of the gas was more specifically on the water purge line or the hydraulic guard of the vent stack. The process gas…
As the airship approached the docking mast, it performed a sharp turn to face into the wind, which was shifting. The engines were run at full speed astern for about a minute to slow the airship. Dust…
The fire developed on a hydrogen bus during filling, and was detected due to the development of smoke and a smell of burned materials. The power cable of the compressor had overheated. Two are the…

Safety slug in the vent pipe of a hydrogen trailer failed, damaging the pipe and causing a hydrogen leak. The following fire damaged several other trailers. [Zalosh and Short, 1978]

In a petrochemical plant, visual inspection detects fumes under the heat insulation of a heat exchanger operating under hydrogen pressure. The first intervention team was mobilized and the unit…

The incident occurred in the hydrogen sulphide absorption tower of the kerosene desulphurisation unit of a refinery. The hydrogen leaked from the liquid level gauge and ignited causing a fire. The…

The incident occurred in a workshop of a bus company. Hydrogen leaked from a tank on a new hydrogen and fuel cell bus parked there. The cause of the leak is unknown. From conversations with the…
The incident occurred at a refinery unit for the desulphurisation of a light heavy oil. This unit was equipped with three hydrogen compressors. Two of them were usually operated and the third was…
The broke out at a hydrogen compressor of the reforming unit of the refinery. Following the safety procedures, the emergency stop of the unit was activated and the unit was decompressed using a…
A hydrogen generator overheated during testing and started a small fire in a power plant.
The fire developed on the hydrogen production unit of a subcontractor in a plant producing metallic wire articles. The cause was a malfunctioning of the hydrogen unit. The production was stopped for…
A fire on one of the two hydrogen units at a gasoline refinery, hindering production.

This incident happened during a test of a hydrogen engine prototype vehicle, equipped with on-board liquefied hydrogen storage. The hydrogen gas leaked from a hose joint of a flexible pipe in the…

The event occurred when attempting to replace a rupture disk in a LH2 vessel. Hydrogen gas was released and ignited. In fighting the fire, liquid nitrogen was sprayed onto a second LH2 vessel…

A fire developed on a mathanation reactor. The methanation reactor vessel was found to be deformed and had a 3-4 inch rupture at a position corresponding to the top of the catalyst bed. It is thougth…

During simultaneous hydrogen venting operations of two hydrogen trailers adjacent to one another, hydrogen was ignited at one, and then the fire ignited the hydrogen venting from the other trailer…

While filling a 9 litre gas cylinder with pressurised hydrogen in the hydrogen storage area, a blast occurred which destroyed the low pressure gauge, followed by a jet fire which damaged the surface…
A man was burned when a fire broke out as a hydrogen cylinder was being changed in a governmental research centre. It was reported that the fire was started by a spark from a wrench. The sprinkler…