Skip to main content

HIAD Causes: System Design Error


The incident started with the cracking of the low-pressure turbine blades. This caused an unbalance to turbine generator rotor which led to the failure of the bearings and the loss of confinement…

During a turbine testing at 100 percent power, a problem developed in the auto-stop trip system, which led to a turbine and reactor trip. The turbine stop valves closed as expected, but after closure…
SYNOPTICs The loss of the hydrogen side sealing oil pump and other problems in the sealing oil system resulted in the coolant hydrogen leaking from the generator. The hydrogen leaked for several…
A leakage and fire occurred during normal operation at a medium-pressure hydrocracker of a refinery. This unit perform a desulphurisation and a decomposition of heavy gas oil. High-temperature and…

The explosion occurred at the hydro-deoxygenation unit of a renewable fuels facility. Part of this unit is a furnace aiming at pre-heating renewable feedstock, recycled renewable diesel, and…

When waste alkali solution was taken out of dumper trucks into a waste liquid storage tank, a reaction occurred in the tank. As a result, the solution in the tank foamed over it, and reached an…
The incident occurred at the direct desulfurization unit of heavy oil. A 130×90 mm oval opening occurred in the bypass pipe of the hydrogen sulphide absorption tower for the circulating gas, at a…
A fire at the exit of the vent line occurred when filling a tube trailer. An employee suspected a flame at the outlet of the hydrogen venting line during the filling of a trailer. , by sawing the air…
A tube trailer was returning to the basis after having delivered compressed hydrogen to a customer site. The vehicle was operated by two drivers taking turns in driving. While traveling on a highway,…
The ignition of a hydrogen leak occurred at a semitrailer connected to a pressure reducing station, while waiting a transfer. The alert was given by personnel of the company cafeteria located nearby.…

A LH2 trailer was delivering at a customer location. The LH2 transfer had just been terminated and the driver was ready to depressurise the trailer to remove the hose. When he started to open the…

During the preparation for a liquid hydrogen transfer from a tanker to a stationary storage system, the safety valve opened and the gas ignited. The incident occurred when a pressure build-up was…

This incident occurred during the delivery of a hydrogen gas container to a customer site. When a worker turned the protective cap of the container, the valve handle turned together with the…

A truck loaded with 22 hydrogen cylinders pallets (370 litres each) was traveling on a national highway. While stopped at a traffic light, it was rear-ended by a large truck which damaged the…

The incident occurred at the residual de-sulphurisation (RDS) unit of a refinery, during the initial start-up phase, consisting of the pressurisation by hydrogen of the unit reactors and the…

This incident occurred at a linear alkylbenzene manufacturing plant. It affected dehydrogenation reactor of normal paraffin, during the operation of catalyst exchange in the reactor. This is usually…
The incident occurred at a hydrogen storage unit serving a catalytic reformer. During transfer of hydrogen from the storage unit to the reformer, a flexible hose was over-pressurised and caught fire.…
A hydrogen fuel tank release caused a fire at a hydrogen refuelling station. A pressure relief valve installed on one of the 18 storage tanks failed at a pressure far below its design opening value.…
A tanker was travelling on a highway, when a passing motorist notified a problem with the tanker to the drivers. They pulled the unit safely off the highway, went to rear of the tanker and opened the…

The chain holding compressed hydrogen cylinders on a lorry broke. Probably the cylinders fell and due to the mechanical impact they released hydrogen resulting in a small fire [Zalosh and Short,…