HIAD Causes: System Design Error


The event started when a gasket in a water pump was blown out. The water pump was situated inside a 100 m long, 10 m wide, and 7 m high building. The pump was feeding water to a vessel containing…

An explosion occurred during calibration of engine. The equipment was covered by a shed and when the valve was operated allowing hydrogen gas to flow through the engine, the gas ignited. The…

After completion of a process using hydrogen an explosion occurred in the vicinity of the vent stack. Cold hydrogen gas was being vented into the atmosphere for about 45 minutes. The weather was…

Several explosions occurred in one of the catalytic reforming units of the refinery, followed by a fire in the same unit. The fire derived from the explosions lasted for almost one day. The…

A series of explosions occurred in thee desulphurisation and catalytic reforming unit of the refinery, followed by fires in the same unit. The establishment is classified as Seveso Upper Tier…

Two hydrogen explosions occurred at a boiling water reactor (BWR). The first explosion occurred at 9:30 a. m. and was mostly confined to the off-gas system. Damage was relatively minor. The second…

The incident occurred when filling a gaseous tube trailer from a liquid hydrogen stationary storage system. The liquid hydrogen cryogenic pump shaft malfunctioning caused a series of explosions…

During the J-2 engine testing program, the engine start tank was pressurised. The pressure raised to an excess of 1500 psi (ca. 105 bar). The venting of the tank was attempted but remained…

The failure of a high pressure hydrogen-based synthetic gas feed line to the ammonia converter produced a sudden explosion followed by a severe fire. One of the operators was fatally injured. The…
The incident happened in an ammonia plant, on the pipe leading hot synthesis gas (syngas) from the synthesis convertor to the first heat exchanger. The pipe cracked, releasing the syngas which did…

Following loading of propellant run tanks, the insulation jacket (filled with perlite) on the conmon vent and pressurisation line for the LH2 storage tank burst. [Ordin, NASA (1974)]

Hydrogen fire in the compressor-turbine chamber of a power plant. The hydrogen leaked from the generator terminal bushing into unventilated terminal segregated bulbar ducting (this is a duct used…

Two successive fires broke out in an interval of few minutes in four cells in the electrolysis room of a chlorine production plant. The technicians brought the fire under control using the fire…
The incident occurred at the recycle hydrogen compressor of a hydro-desulphurisation unit. The compressor was equipped with a suction rectifier. The drainpipe of this rectifier had been corroded…
A fire occurred on a valve of a hydro-desulphurisation unit in a refinery. The failed gland was modified and fire extinguishers by steams were installed permanently .

The incident occurred in the fired heater of a hydrocracking unit. Due to overheating, about 250,000 pounds of hydrogen and naphtha mixture were accidentally released into the firebox of the fired…

This incident occurred at the fired heater of a non-further specified reactor of a refinery (probably a hydro-desulphurisation unit). A tube of the fired box failed releasing a mixture of hydrogen…

The incident occurred at a power generator during the shutdown of one reactor unit. Hydrogen leaked from the cooling circuit of the generator due to damaged sealing. The hydrogen ignited. The fire…

One turbine was stopped for minor repairs and adjustment. The generator’s excitation breaker and air-operated disconnect breakers were opened. When the turbine generator had nearly completed its…

The explosion occurred in the condenser area of a steam turbine, two hours after the unit tripped due to a stator earth fault. The stator earth fault had damaged two hydrogen cooler tubes, which…