HIAD Causes: System Design Error


The incident occurred at end of a hydrogen fuel pump test, when large volume of gaseous hydrogen was vented off. An explosion occurred at or near the top of the vent stack, with damage to stack…

A large quantity of hydrogen was being vented to atmosphere during pre-chill operations. Normal pre-cooling time was about 45 minutes, but due to technical problems, the pre-cooling continued for…

The incident occurred at an indirect oil desulphurisation unit, and originated on a piping at the outlet of a heat exchanger. The exchanger was located in the furthermost downstream of the reactor.…
A fire and explosion occurred at a catalytic reformer unit. The fire centred between the reactors and fired heaters of the reformer and resulted in extensive damage to the unit. The explosion rocked…
The incident occurred at a tank of the chlorine electrolyser of a water treatment plant The plant products were sodium hypochlorite as a disinfectant for water treatments. The production process used…
The accident occurred in the hydro-cracking unit, specifically in its sulphur recuperating system. The location was on a 8" piping, which cracked at a a 90° bend. Due to the loss of confinment, a…
The accident started with a leakage of distilled petroleum intermediate and hydrogen in the desulphurization unit of the distilled intermediate. Both substances ignited and exploded, with a later…

A hydrogen explosion occurred at the hydrogen storage unit of a power generation plant. A burst disc opened, releasing approximately 3 tons of hydrogen. The leaked hydrogen formed an explosive…

An explosion and fire occurred at night inside a unit for the synthesis of toluene di-amine. The process implied the hydrogenation of di-nitrotoluene in presence of isopropanol as solvent and Raney…
At a soaking facility of an industrial plant in the metallurgy sector, the pipeline between a supply tank and a feed pump became clogged and the autoclave only received sporadic feed. Problems had…
on a Sunday morning, in a ceramic factory, a leak on a 100 m³ tank containing 370 kg of hydrogen caused an explosion. The generated pressure wave causes significant damage to exterior buildings…
Hydrogen ignition during the (illegal) filling of a balloon. Two men had decided to fill in a weather balloon with hydrogen in a storeroom located in the basement of a block of flats. Their idea was…
This event occurred when a hydrogen-carrying trailer was supplying hydrogen to a chemical plant. Instead of filling the hydrogen stationary storage, large quantities of hydrogen were transferred from…

The event occurred during the testing of a LH2 pump. When the air turbine pump drive was initiated, the cool down of pump loop was underway, and the speed had increased to design condition and…

This incident occurred at a company producing building elements. The process implies the production of a small quantity of hydrogen, which is usually dispersed into the environment without…
An explosion occurred in a water skim tank associated with a reactor for dehydrogenation of the ethyl benzene. The reaction products from this dehydrogenation reaction consisted in a mixture of…
A blowback occurred when adding iron powder to an EDTA solution at 60 C in a chemical reactor (EDTA = Ethylene-diamine-tetra-acetic acid ). Hydrogen was produced by a chemical reaction and ignited by…

A explosion occurred in the gas and dust treatment system for the aluminium holding furnaces at a metallurgical plant. The explosion caused the failure of the treatment system, the operation of…

An explosion occurred at the fume treatment unit of a foundry. The fumes contained chlorine, used in the metal treatment process. The treatment unit function by spraying water and caustic soda.…

The incident occurred at a silane production plant. A ‘neutralization container’, part of the "Contact Mass Preparation" process unit, exploded. The bursting was caused by the accidental production…