HIAD Causes: System Design Error


A hydrogen jet fire from a pipe was detected by a night operator making rounds in a solvent production unit. The unit's emergency response team managed the fire in minutes. Operators stopped the flow…
[NOTE of HIAD Validator: the attribution to hydrogen formation as cause of the explosion is 'probable 'but not fully demonstrated]. Two explosions in two different sprinkler systems occurred, wit the…

Hydrogen as carrier gas was provided to a reactor gas chromatograph by several compressed hydrogen bottles. The bottles emptied rapidly, but the loss of carrier gas could only be detected when the…

This incident occurred at a 70MPa hydrogen refuelling station. After completing a filling test, the pressure in the filling hose suddenly dropped. A worker heard the hissing sound of a hydrogen…

Following the first flight of the Montgolfier brothers, the first severe accident with hydrogen on a Montgolfier-balloon occurred in 1785, when trying to cross the Channel from France to England. Two…
The event occurred at a pit furnace for metal component treatments. The hydrogen feed system for the furnace developed a leak, located on the hydrogen dryer inside a shack attached to a building. The…
An explosion took place at the hydrodesulphurisation unit of a refinery's crude oil. A leak occurred on suction line of a hydrogen compressor used for the re-circulation of the hydrogen required for…
A fire broke out on the world’s first hydrogen carrier vessel shortly before setting sail from Australia to Japan carrying the world’s first international shipment of liquefied hydrogen. A flame was…
The charge pump on a hydro-desulphuriser unit tripped. The charge flow control valve then opened wide on low flow. The high pressure hydrogen supply to the unit flowed backwards through a faulty non…
During a leak test performed on a new retention basin of a chemical plant, one of the walls of the structure collapsed on a rack of 4 pipes located nearby and caused the rupture of the supports and…

During a transfer of liquid hydrogen from a commercial tanker to a stationary receiving vessel, a leak developed in the bayonet fitting at trailer-vessel connection. The leak produced a hydrogen…

A CGH2 trailer-tractor arrived at a customer’s site for delivery. When stopping at gate and coming out of the cab, the driver noticed a noise coming from the rear of the trailer. The driver opened…

A tube trailer carrying compressed hydrogen was travelling along a city road, when the drivers heard an abnormal sound from behind. They stopped and discovered that hydrogen was leaking from the…

The incident occurred when refuelling with hydrogen a fuel cell forklift. The hydrogen was provided by a mobile refuelling station. The filling of a second forklift of the day had just begun, when…

A liquid hydrogen tanker was returning to base terminal after having delivered at a space centre, when the driver noticed excessive venting of hydrogen gas vapour from the rear . The driver pulled…

An empty liquid hydrogen tanker was returning to the base terminal after having delivered at a customer (approximately 4 hour and 200 miles). The drivers noticed vapour coming from the vent stack…

A liquid hydrogen tanker-tractor was travelling on a highway, when the drivers noticed vapour coming from the tank. They pulled the vehicle safely off the road and discovered that the vapour was…

A leak occurred at the compression unit of the refuelling station. The employees had just initiated the normal procedure of starting up the hydrogen production equipment, and opened the three shut…

A leak occurred while refuelling a fuel cell vehicle with hydrogen at a mobile hydrogen refuelling station. The hydrogen gas leak detection alarm (at 1% LEL) on top of the dispenser body went off,…

The drivers of a CGH2 tube trailer-tractor was travelling to a delivery. they stopped to perform a visual walk-around inspection of the vehicle and discovered an audible leak coming from the neck…