HIAD Causes: System Design Error


A hydrogen leakage occurred in the ammonia workshop of a plant manufacturing nitrogen products and fertilizer (classified SEVESO high threshold). It was detected by an operator in charge of safety…
The incident occurred at an alkaline electrolyser in a renewable hydrogen production plant. It consisted of an explosion which brough to the release of potassium hydroxide solution (KOH) from the…

The event occurred during a pressure testing of a LH2 pump discharge system. A weld joint failed at an internally tied bellows. The weld failed at 1100 psi (ca. 76 bar) while the test pressure…

During transfer of LH2 from a 200,000 gallon (760 m3) storage vessel to a road trailer, loss of vacuum was detected due to a crack in the outer vessel. The crack was located below an elbow of the…

A liquid hydrogen tanker (with a water capacity of 2000 l) was passing a highway interchange, when the safety valve of the tank activated, releasing hydrogen gas. The drivers stopped first on the…

A rupture disc opened on a 76 m3 (20,000-gallon) liquid hydrogen tank, causing the vent stack to release cold gaseous hydrogen. The gas ignited causing a fire on the vent stack's outlet.…

During the transit of 10 000 gallons (ca. 39000 l) LH2 transport vessel, the venting rate became extremely high . The annular vacuum appeared to be lost showing large patches of condensed water at…

The pressure building valve opened due to vibration from the road, causing the build-up of the internal pressure. The drivers performed a hydrogen venting and re-sealed the valve. [Zalosh and…

This event regards the degradation of steels used in the heat-exchangers of a reformer of a refinery. An inspection by non-destructive ultrasonic techniques revealed material degradation of the steel…
Motorway accident which involved a large quantity of vehicles and a gaseous tube trailer which transported gas hydrogen in pressure. Some cars were burning under the back part of the gaseous tube…
A potentially explosive situation was reported by safety inspectors at a nuclear waste tank. The waste slurry had formed a thick crust which was trapping hydrogen being continuously generated…
An operator noted a loose tube sheet flange stud on a high temperature, high pressure heat exchanger in an hydrodealkylation unit. The stud was found to be cracked through. Analysis proved to be made…

A fuel cell and hydrogen vehicle terminated the refueling, but the dispenser nozzle could not be completely disconnected from the the vehicle receptacle. It could be disconnected only after…

An empty liquid Hydrogen tanker was returning to the base terminal from a delivery at a space centre. At the departure, the internal vessel pressure was 8 psig. At the first safety check, the…

During a leak check of a flash point material testing chamber, the chamber was inadvertently over-pressurised with GH2. The glass port in the door burst, causing damage to the chamber and to the…

In a paper plant, an explosion occurs in a paper pulp tank while 2 workers were carrying out pipes cutting with a grinder on the roof of the tank. Detailed analysis of the event was performed by two…
A hydrogen explosion ruptured and fragmented a 6-inch steam condensate pipe elbow at of a nuclear plant. The component affected was a steam piping of a heat exchanger used for removing residual heat…
A cryogenic hydrogen laboratory had a power outage. The cryogenic hydrogen storage was no longer being cooled, therefore temperatures and pressures within the storage system started rising. There…
A hydrogen leak occurred at a tube bundle container at the loading and unloading bay of a PSA (Pressure Swing Adsorption) hydrogen production plant. During the hydrogen filling process, a worker in…
A hydrogen release and subsequent fire occurred at meter station of a pipeline transporting hydrogen to a refinery. Local refinery emergency response team responded and secured the area. The pipeline…