The vehicle puling a compressed gas hydrogen trailer was on a highway transporting 420 kg of hydrogen. A car turn in front of it running a red light, so that the CGH2 trailer did not have time to…
The event occurred while starting a new production cycle. The production supervisor issued specific instruction on a new production cycle to a technician. The technician did not follow them in the…
This event occurred at a theatre building. A contractor was conducting routine maintenance on a dry pipe sprinkler system in the basement of the theatre. By opening the pipe, an explosion occurred…
The event occurred during the decommissioning of a nuclear power plant. It involved a tank containing 100 kg of residual sodium from the decommissioned experimental nuclear reactor which was using…
Heavy rains (more than 600 mm in 1 day) had flood a factory manufacturing calcium core electrical conductors. The power supply was cut off. The water came into contact with the calcium stored in 150…
The event occurred in a silicon hydride (SiH) emulsion production process inside an enclosed production building. The reaction was ongoing when one of the tank started overflowing with foam. The…

The incident occurred at a pulp mill plant producing fluting media. The explosion took place at a pulp storage tank and was caused by the combustion of a hydrogen-ammonia gas mixture. The roof of…

The incident occurred in an electrostatic filtration unit. When flushing with air during the start-up phase of a sulphonation plant, an explosion occurred in the upper part of the electrostatic…
The bolts on a not further specified industrial facility failed after approximately 4000 hours in service (approximately 18 months in service). Their failure bolts causedH2S leaks. The bolts…
A fire and a series of explosions occurred on a petrochemical plant, causing damage to process vessels, containment walls and process utility piping. It is believed that lightning struck a two story…

A small hydrogen cylinder was beeing filled at a facility for high-pressure testing. The cylinder had a nominal working pressure of 2000 psi (approximately 140 bar) and the filling a target…

On a highway, a truck loaded with 400 gas cylinders crashed at night for an undetermined cause against a concrete wall and overturned. It slipped 150 m, before several 200 litre cylinders of hydrogen…

Early in the morning a hydrogen tube trailer experienced a tire fire and pulled onto the road shoulder. The driver attempted to extinguish the fire with the fire extinguisher on the vehicle. Heat…

A CGH2 tube trailer-tractor was travelling to deliver hydrogen to a customer, when a fire developed on right side of the tractor around the rear of the hood and passenger side door. Very quickly…

The HRS canopy was lower than the forecourt canopy. Heavy duty vehicles (HDV) were not noticing the issue and hitting the HRS canopy assuming same height. The canopy has now been repaired twice, and…

A stainless steel manifold ruptured during experimental operation. The manifold was made of stainless steel and had a diameter of three inch (7. 5 cm). The hardware was off-the-shelf, slightly…

The incident occurred in a biogas-fed Solid Oxide Fuel Cell Stationary system, working in CHP mode. A sudden stop of the biogas feeding line caused the safety shutdown of the plant (SOFC module). The…
A vapour explosion, followed by a fire, occurred at a drier in a plant making titanium sponge. When titanium containing water was put into the drier, it came to contact with the edge of the…

The incident occurred at a storage tank of an organic chemical plant. The storage tank was containing cyclo-dodecane (C12H24, melting point: 60 °C), and a tank trucks was being filled at the…

This event occurred at the accelerator bubble chamber facility. During final stages of chmaber cooldown and its loading with LH2 (95% fill, about 95 gallons), an explosion and fire occurred…