Near the end of the process of filling a gaseous hydrogen tube trailer at a liquid hydrogen trans-filling station, a safety pressure-relief device (PRD) rupture disc on one of the tube trailers ten…

A compressed hydrogen tube trailer was fully loaded and parked, when a rupture disc on one of the tubes failed. The escaping hydrogen ignited. 9583 cu ft were released. [Zalosh and Short, 1978]…

The incident occurred at the site of a gas production company. During the filling of a compressed hydrogen trailer, an end plug thermal pressure relief device (TPRD) had an unplanned activation.…

The incident occurred at the residual de-sulphurisation (RDS) unit of a refinery, during the initial start-up phase, consisting of the pressurisation by hydrogen of the unit reactors and the…

A leak occurred at an underground steel pipeline (6 inch) transporting pressurised hydrogen (75 bar). The leakage lasted for at least several hours, but it cannot be excluded that the leakage started…
A hydrogen fuel tank release caused a fire at a hydrogen refuelling station. A pressure relief valve installed on one of the 18 storage tanks failed at a pressure far below its design opening value.…
The truck was delivering hydrogen to a steel products plant. It contained approximately 8500 gallon of liquid hydrogen. The operation of transfer to the customer tank had just terminated. The fire…

A liquid hydrogen tanker was preparing to transfer hydrogen to a stationary tank belonging to a manufacturing facility. The tanker was being pressurised before transfer, when a burst disc failed…

An empty LH2 trailer was travelling back to the baser to load new LH2, when one of the truck tyre (the inner tire on the driver’s side rear axle) blew causing sparks and smoke. The driver pulled…

The chain holding compressed hydrogen cylinders on a lorry broke. Probably the cylinders fell and due to the mechanical impact they released hydrogen resulting in a small fire [Zalosh and Short,…

A truck was transporting 35 compressed hydrogen cylinders (7 m3) to a sales office when it suddenly got a flat tire, causing the truck to overturn. The cylinders were thrown onto the road and gas…

The incident occurred at an ammonia production plant. The plant was starting, when a section of piping between the secondary reformer and a waste heat boiler (“transition pipe”) ruptured. Process…

Hydrogen and butyl acetate released and caught fire on the vent of a hydrogenation reactor, part of a dyes manufacturing plant. The pressure inside the reactor increased due to excess hydrogen…
The event occurred at the flanges on the outlet of a desulphurization reactor, which was working under about 300 degrees C. The flanges and bolts were cooled down by a large amount of rainwater which…
A fire started in a refinery's gas oil desulphurization unit. The purpose of this unit is to separate sulphur from hydrocarbons and to do so, the latter are raised to 340°C in the presence of…
A gas leakage (approximately 70% hydrogen, 21% nitrogen and the rest carbon monoxide and other impurities) occurred at the connection between a temperature measurement casing and a flange in the…

An explosion of a mixture of hydrogen and hydrocarbons occurred at a fired heater of an ethylene unit of a chemical plant. The bad weather caused the shut down of the boiler units. This shutdown…

A hydrogen leak in the hydrogen compressor unit of a filling station ignited causing the shut down of the whole station. The loss of containment was due the failure of a tie rod (diameter ~64mm) ,…

The event occurred at the in the distillate hydrotreater unit of a refinery. This unit was using hydrogen to remove sulphur from a hydrocarbon feedstock. A 12-inch overhead pipe ruptured with a loud…
The accident originated in the isomerisation unit and propagated to the benzene saturation unit. The accident source was a mechanical rupture of one of the two compressors used to transfer hydrogen…