HIAD Causes: Material/Manufacturing Error


The incident occurred in a catalytic reforming unit. At 13:41, a leak occurred at the 90° elbow of a pressure pipe containing a mixture of hydrogen and naphtha. This pipe was located between the pre…
The event started at the effluent pipe of one of the hydro-cracking reactors, which broke and released a mixture of hydrogen, light gases (methane, butane), light gasoline; heavy gasoline; gas oil.…
The accident happened in an anhydrous ammonia plant, commissioned in March 1977. Hydrogen accumulated inside a Benfield solution (hot potassium) storage tank and was ignited by a static charge, which…
This incident occurred at the hydrogen production and storage unit of (probably) a power plant using hydrogen as a coolant of the turbine-generator system. Hydrogen was produced probably by water…

A compressed hydrogen container was being filled at a refuelling station. The container was belonging to trailer and consisted in a bundle of tubes connected via piping to a manifold and filling…

An explosion occurred in a nitrogen wash cold box (outside the equipment) after a several day cold shutdown followed by a derime with nitrogen. It is assumed that ice may have split tubes…

The incident occurred at the hydrofining unit, refining a mixture of petroleum and diesel into Euro 3 and Euro 4 diesel. A pump feeding the reactor with the process mixture failed. Following the…

An explosion occurred at a hydrogen compressor of a polysilicon plant. The head of the compressor was blown off and the released hydrogen exploded causing extensive damage to the building and to…

A crack occurred in a storage tank (300 kg of hydrogen) releasing gaseous hydrogen to atmosphere. The vapour cloud exploded with an apparent centre of explosion 9 m above ground, with a energy…

[Note HIAD validator: this an incident where the hydrogen systems were invovled as effects of the initiating event. There is nevertheless and addtional possible contribution by hydrogen…

A series of explosions occurred in thee desulphurisation and catalytic reforming unit of the refinery, followed by fires in the same unit. The establishment is classified as Seveso Upper Tier…

The accident occurred in the Reactor 6 used to carry out the hydrogenation of a pharmaceutical intermediate. The operation of the plant was organized in two shifts. Since the hydrogenation at Reactor…

A steel hydrogen pipeline failed with a circumferential rupture, at a location where a leak had been already detected and repaired. The leak was discovered during a one-call response for planned…

During a test of an 8 foot scale tank loaded with LH2, the tank burst at 77 psi (ca. 5. 3 bar) destroying the test installation. No fire or explosion occurred and the area control was successfully…

The incident happened in an ammonia plant, on the pipe leading hot synthesis gas (syngas) from the synthesis convertor to the first heat exchanger. The pipe cracked, releasing the syngas which did…
A dual phase hydrogen tanker was expected to refill the storage of a refuelling station for buses. Due to the failure of the a bolt of the tanker pump, the refuelling could not take place. This…

The fire occurred at the turbine-generator unit of a power plant. A first hydrogen leakage took place from a 4 bolt flange. It ignited producing a small but intense flame, causing further hydrogen…

At a rocket engine testing facility, a combustion experiment of the pre-burner (gas generator for driving the turbopump) was being conducted, before testing the turbopump. The pre-burner is the…

This incident occurred at an aromatics manufacturing plant. A staff member patrolling the plant heard a strange noise and rushed to the site, where he discovered a hole in a pipe, from which hydrogen…

This incident occurred at the fired heater of a non-further specified reactor of a refinery (probably a hydro-desulphurisation unit). A tube of the fired box failed releasing a mixture of hydrogen…