During a gaseous hydrogen trailer filling operation, a burst disc relieved, causing a gas release. The gas flow caused the vent pipe to separate at the flared tube fitting, resulting in a fire.…
A CGH2 tube trailer was parked at a gas shipping site and was transferring gaseous hydrogen to a stationary storage system. The transfer hose failed releasing hydrogen, which ignited. The…
A release of hydrogen occurred on a trailer during filling a stationary hydrogen storage tank. A pressure relief device (burst disk) on one of the tube failed prematurely and released hydrogen.…
The vacuum on a liquid hydrogen tanker was lost, resulting in a hydrogen release, both manually and through bursting of burst disc [Zalosh and Short, 1978]
A faulty burst disc on a liquid hydrogen tanker failed prematurely releasing 750 cu. ft. of of hydrogen. [Zalosh and Short, 1978]
Due to a loss of confinement of the inner shell of the liquid hydrogen tank, the vacuum of the external shell was destroyed. The reduced thermal insulation capacity of the shell caused evaporation…