HIAD Causes: Material/Manufacturing Error


This event occurred at a theatre building. A contractor was conducting routine maintenance on a dry pipe sprinkler system in the basement of the theatre. By opening the pipe, an explosion occurred…
Hydrogen leak due to a fault with non-process related battery equipment. After reporting the hydrogen leak, fire crews have been called to a gas terminal. The leak was due to a fault with non-process…

A vessel exploded at a plant producing pharmaceutical products. At the time of the incident, the plant was producing a substance called Dekon 139. The Dekon had already been synthesised, and…

Following a loss of power the failure of a backup battery causes an alarm in a hydrogen storage facility. Consequently, a valve on the purge circuit and 30 m3 of hydrogen is released to the…
Hydrogen leaked from a hydrogen compressor, ignited causing an explosion and a fire. The hydrogen fire further ignited roofing materials which had fallen down as the result of the explosion. The…
An explosion occurred in a electrolyser cell, blowing off the cell's vent cover and severing a low-pressure chlorine gas pipeline. , what caused a release of chlorine in the building, The event…
The explosion took place in the hydrogen gasometer. The bell in the gasometer was lifted 15-20 m straight up and cracked. The cover fell down on the pipe bridge besides the gasometer. The cylindrical…

A Bourdon tube ruptured in pressure gauge after 528 hours of operation in LH2. The alarm sounded, the system was isolated and then vented. [Ordin, NASA (1974)]

The soldiers of the Royal Prussian Air Ship Division stored large amounts of hydrogen gas. They kept some 1000 cylinders in a shed. On 25 May 1894 about 400 of them burst without apparent reason.…

A continuous venting of hydrogen from a LH2 tanker occurred during highway transportation. Trailer delivered at test site and vacuum pressure checked to be less than 1 micron. The tank pressure…

Discharge pressure of a hydrogen compressor on a chloride plant fell to alarm level without any prior warning and simultaneously three bumps were heard. Smoke was seen coming from the hot motor…

A tube trailer was driving on a highway, when the drivers noticed in the back camera smoke coming from the rear of the vehicle. After stopping the vehicle on the shoulder, they discovered a fire…

This near miss occurred at metal smelting unit of a foundry. At 9:45 a. m. , due to a power outage, the cooling pumps of two furnaces containing nickel and chromium stopped. One of the two furnaces…

[Note HIAD validator: this an incident where a hydrogen system was affected, as effect of the initiating event, overpressure of LH2 tank with helium, but it is not a LH2 incident]. The second…

This event with minor hydrogen releases occurred during the operation of a hydrogen compressor. The compressor was part of a mobile hydrogen production unit and connected to a bundle of cylinders…

During a filling at a hydrogen refuelling station, the station was shut down due to a gas detection. The leak was extremely small and difficult to locate but the gas was directed upwards towards the…

During the pump operation of a liquid hydrogen tanker, the vent valve was opened rapidly and the hydrogen detonated above the vent stack. The rapid valve opening was aimed at initiating a good…

This event occurred at the accelerator bubble chamber facility. During final stages of chmaber cooldown and its loading with LH2 (95% fill, about 95 gallons), an explosion and fire occurred…

The explosion occurred in the compressors unit of the plant. Witnesses reported a cloud of yellow smoke and a fire ball at its bottom. This first event was followed by a fire fed by a hydrogen pipe…
An explosion and fire occurred at around at a company specialised in hydrogen storage in slid materials. The accident occurred while a press used to compact magnesium hydride and natural graphite…