HIAD Facility - Operational Condition: Normal


The chain holding compressed hydrogen cylinders on a lorry broke. Probably the cylinders fell and due to the mechanical impact they released hydrogen resulting in a small fire [Zalosh and Short,…

Hydrogen enrichment of the gaseous phase in a rail tanker initiated an exothermic reaction between hydrogen and chlorine which in turn triggered fire of iron chloride.

This incident occurred at a reactor at a succinic acid manufacturing plant. The reactor was had just terminated the hydro-generation of maleic anhydride for manufacturing succinic acid. Hydrogen…

A truck was transporting 35 compressed hydrogen cylinders (7 m3) to a sales office when it suddenly got a flat tire, causing the truck to overturn. The cylinders were thrown onto the road and gas…

The incident occurred while delivering seven compressed hydrogen cylinders to a customer site. The store employee had already removed four cylinders from the delivery truck and carried them…

A vehicle (non-further specified) carrying two hydrogen gas cylinders had to brake suddenly. The two cylinders tipped over, damaging the valve and causing hydrogen gas to leak out and ignite. The…

A road transportation incident. A road tanker of hydrogen overturned and caught fire.

The incident affected a hydrogen gas purification unit of a chemical plant. A hydrogen release and ignition occurred at the joint between a pressure gauge attached to the inlet piping of an…

A hydrogen leak occurred from a screw connection of a pressure gauge installed on the hydrogenation pre-feeder line alcohol production plant. Due probably to static electricity, the hydrogen…

A fire occurred at a hydrogen refuelling station for buses. The incident was initially reported as an explosion due to a loud noise and vibrations felt in nearby buildings. However, subsequent…

This incident occurred in a unit processing vegetable oils and fats. the explosion occurred in a hydrogenation facility, specifically where hydrogen is processed with a very high-pressure (400 bar).…
A fire broke out following a hydrogen leak on the Cyclododecane unit in a chemical plant. A plume of smoke became visible outside the site. The fire was brought under control by putting the unit in…
Hydrogen and butyl acetate released and caught fire on the vent of a hydrogenation reactor, part of a dyes manufacturing plant. The pressure inside the reactor increased due to excess hydrogen…
The event occurred on a hydrogen pipe of a sodium chlorate plant. The on-duty field technician noticed a self-sustained ignition on the pipe. The flare-like flame of less than one metre in height was…
In an chlorine production plant, vented chlorine and hydrogen, auto ignited when the hydrogen concentration was allowed to exceed 5% and the mixture mixed with air. [Zalosh and Short, 1978]

The event occurred at a centre handling metal waste. A fire broke out in a container for aluminium alloy shavings, while handling it with a grapple excavator. The fire spread throughout the entire…

The event occurred at the flanges on the outlet of a desulphurization reactor, which was working under about 300 degrees C. The flanges and bolts were cooled down by a large amount of rainwater which…
A fire started in a refinery's gas oil desulphurization unit. The purpose of this unit is to separate sulphur from hydrocarbons and to do so, the latter are raised to 340°C in the presence of…
the fire was detected by an employee during the normal inspection tour. It was caused by the ignition of a leak of process gas (hydrogen, methane and water vapour) from the reforming furnaces. The…
A gas leakage (approximately 70% hydrogen, 21% nitrogen and the rest carbon monoxide and other impurities) occurred at the connection between a temperature measurement casing and a flange in the…