HIAD Facility - Operational Condition: Normal


A hydrogen-air explosion occurred outside a hydrogen compressor. Gaseous hydrogen was released from the vent stack due to a premature activation of a relief valve. The flammable atmosphere ignited…

An explosion occurred at a hydrogen compressor of a polysilicon plant. The head of the compressor was blown off and the released hydrogen exploded causing extensive damage to the building and to…

A crack occurred in a storage tank (300 kg of hydrogen) releasing gaseous hydrogen to atmosphere. The vapour cloud exploded with an apparent centre of explosion 9 m above ground, with a energy…
In an electricity production plant, hydrogen leaked from a tank supplying the colant to the generator. The leaked hydrogen iognited and formed a fireball. Possible involvement of sealing oil not…
The event started when a gasket in a water pump was blown out. The water pump was situated inside a 100 m long, 10 m wide, and 7 m high building. The pump was feeding water to a vessel containing…
An explosion, accompanied by abundant black smoke, occurred at an ammonia production plant. An ignited leak of hydrogen in the ammonia production unit had spread to the pressure circuit carrying…
The incident occurred at the hydrogen coolant system of the power generator. The control panel door for the 32 hydrogen dryer blew off due to a small hydrogen explosion. No one was injured in the…
The release and fire occurred during what appeared to be a normal operation in a reactor section of a Residue Hydrotreater Unit, when an eight-inch pipe connected to a heat exchanger failed at the…
The explosion followed a hydrogen leak on a unit conditioning hydrogen. The leak was caused by the mechanical rupture of the membrane of a pressure release device which was part of a pressure…
Several explosions occurred in one of the catalytic reforming units of the refinery, followed by a fire in the same unit. The fire derived from the explosions lasted for almost one day. The…
Two hydrogen explosions occurred at a boiling water reactor (BWR). The first explosion occurred at 9:30 a. m. and was mostly confined to the off-gas system. Damage was relatively minor. The second…
The accident occurred in the Reactor 6 used to carry out the hydrogenation of a pharmaceutical intermediate. The operation of the plant was organized in two shifts. Since the hydrogenation at Reactor…

The incident occurred when filling a gaseous tube trailer from a liquid hydrogen stationary storage system. The liquid hydrogen cryogenic pump shaft malfunctioning caused a series of explosions…

The failure of a high pressure hydrogen-based synthetic gas feed line to the ammonia converter produced a sudden explosion followed by a severe fire. One of the operators was fatally injured. The…
A tank of liquefied hydrogen felt down in a chemical plant. The tank, containing 100 m³ of liquid hydrogen, was installed on a concrete plate, which failed. The hydrogen started leaking from the…
The incident happened in an ammonia plant, on the pipe leading hot synthesis gas (syngas) from the synthesis convertor to the first heat exchanger. The pipe cracked, releasing the syngas which did…
A dual phase hydrogen tanker was expected to refill the storage of a refuelling station for buses. Due to the failure of the a bolt of the tanker pump, the refuelling could not take place. This…

This incident consisted in the dropping of a gas cylinder and the release of its content due to stress corrosion

A driver of a fuel cells vehicle terminated the refuelling and drove away without disconnecting the fueling hose from its vehicle. The breakaway of the fueling hose was supposed to open, but did…

A collision between two vehicles occurred at the corner of two streets. One vehicle was a fuel cells and hydrogen vehicle (FCEV), the other was a conventional one. Its driver incorrectly did not…