HIAD Causes: Unknown


A pipe of a hydrogen storage system (240 m³) breaks. The staff is evacuated and a perimeter of protection is put in place.

a hydrogen recycle compressor shut down unexpectedly, resulting in flaring activity with visible smoke.
A joint failure allowed a mixture of hydrogen and nitrogen into the atmosphere. Failure of double cone joint on waste heat boiler in synthesis loop caused release of synthesis gas at 28. 7 MPa and…
The incident occurred in a plant producing organic chemistry products. Hydrogen leaked briefly from an hydraulic valve. There has been no victim.
A hydrogen leak alarm was received in the control room from the reformer of the hydrogen plant of a chemicals manufacturing facility. The reformed was depressurised and the leak stopped. The leak was…
A release of hydrogen took place in a metal cold rolling workshop. The hydrogen leaked from a cylinder of 15 m3, which was part of a storage system of 250 m3. Half of the workshop and the surrounding…
A small hydrogen leak occurred during routine maintenance on an oil refinery unit not in operation.
Leaking hydrogen ignited at a plant that processes bitumen from oil sands.
A hydrogen leak occurred on one of the cylinders carried by a truck. After the leak was stopped, the vehicle was escorted by the fire brigade and taken to a laboratory for inspection. [Nore of the…
A hydrogen leak occurs in a manufacture of steel pipes. The leak is detected and the alarm is triggered.
The leak occurred on the inlet pipe (P=21 bar, T=320°C) of the diesel desulphurization reactor of a refinery. Hydrogen and diesel fuel were released in the gas phase. The hydrocarbons contaminates…
The release occurred at a dyestuffs intermediates plant. Hydrogen escaped from leak in pipeline connection to a cylinder. Householders nearby evacuated for a short while.

Compressed hydrogen escaped from reactor due to faulty gasket [Zalosh and Short, 1978]

The pressurisation line on the nozzle skirt of a liquid hydrogen tank ruptured at welded section. Two tests were underway at the same time; one was a pressure test up to 1850 psi (ca. 128 bar) in…

Around 60 people gathered in a small theatre at a shopping centre to watch an array of scientific experiments, including a "small hydrogen explosion. " Several children suffered second degree burns…

The incident occurred in the new Residue Upgradation Facility unit of the refinery, which converts the heaviest oils from crude oil into high-quality, cleaner fuels such as Euro 6 diesel. The unit…

A small fire occurred at the vent stack of an ammonia processing unit in a plant producing fertilisers and other nitrogen-based chemicals. A safety shutdown procedure of the ammonia processing…

A liquid hydrogen tanker was travelling on a higway, when the vacuum guranteeing the thermal insulation of the tank started to degrade. The increased heat transfer caused a pressure build-up and…

A LH2 trailer was delivering liquid hydrogen to a customer. Once finished the delivery, the driver noticed a leak on the piping between the trailer and vent valve inside the side cabinet. The…

Following a trip caused by the safeguarding of an ammonia production line, the syngas released into the atmosphere and ignited.