HIAD Causes: Unknown


A gas manufacturing plant, one pallet consisting of nine (9) cylinders fell to the ground. The discharge valve of one cylinder (261 cubic feet of hydrogen) was damaged and the entire hydrogen…

The leak occurred on a process pipe of a pressurized at 17 bar and located 3. 5 m from the ground The gaseous mixture composed of hydrogen, methane and hydrogen sulphide (density: 0. 6) was released…
A hydrogen compressor had a major malfunction resulting in serious cavitations, vibrations and dead heading of the 1st stage. The incident resulted in 5 of the 8 lower head bolts on the first stage…

The driver of a hydrogen tube trailer stopped for a rest break and heard an audible leak from the composite tube mounted on the trailer. Local Fire department, medial emergency services and the…

The driver of a hydrogen bus reversed into a post. There was some small material damage to the bus. No leakage of hydrogen (or other gases) occurred.

The trailer experienced a tire/wheel fire at the rear of the tube trailer. The fire deteriorated the hand valve packing on one of the tube causing a slow leak of hydrogen. The trailer consisted of…

A fire started on the brakes of a truck carrying hydrogen. Due to the risk of extension of the fire to the hydrogen, the fire brigade install an emergency area until the fire is extinguished. There…
A deflagration occurred during shutdown of a reactor used for ammonia synthesis. It was followed by a jet fire. The hydrogen leak was probably due first to the lower seals, followed by another leak…
A hydrogen leak was detected in the dispenser pump causing the alarm to sound.

A mixture of hydrogen and diesel leaked and ignited on a desulphurisation unit of a refinery. The emergency plan was initiated few minutes later. The unit was shut down and the leak was stopped.…

This near miss occurred at a CHP plant operation with a SOFC. During the heating phase, the SOFC stopped due to the opening of the mainpower switch. This was due to a contact problem inside the SOFC…
Hydrogen explosion on NPO "Azot" in Rovno, Ukraine.
The incident took place in compression room of methanol synthesis manufactory. As a result of the destruction of a pipe, a mixture of pressurised gases (mostly hydrogen) filled compression room and…
An explosion at a hydrogen recovery plant resulted in the injury of 10 people.
An explosion occurs during testing of the hydrogen feeding of an engine in the Spatial Agency Centre.

A series of explosions occurred in a converter where hydrogen is extracted from ammonia. A fire occurred as a result of the incident.

An explosion and fire occurred on a reformer at a fertiliser plant. Source of ignition was auto ignition or electric motor.

Failure of 400 mm pipe at 1. 7 MPa caused release and ignition took place 10 seconds later.

A runaway chemical reaction happened in a reactor containing methanol and a substance to be hydrogenated. A large quantity of hydrogen was released; a balloon containing a borohydride exploded.…

An explosion and a fire occurred at at a hydro-treatment unit of a chemical plant for lubricants. Plant own emergency response team was activated, assisted from local fire and emergency Services and…