HIAD Facility - Operational Condition: Normal


An operator on patrol discovered a flame coming from the heat exchanger flange of a gasoline hydrodesulphurisation plant and reported it. The plant was immediately shut down. An investigation…
Damage of shipping containers of a ship, due to the reaction of phosphor pentoxide with wine, which lead to the production of phosphoric acid and hydrogen. The overpressure was successfully…
Discharge pressure of a hydrogen compressor on a chloride plant fell to alarm level without any prior warning and simultaneously three bumps were heard. Smoke was seen coming from the hot motor…

Early in the morning a hydrogen tube trailer experienced a tire fire and pulled onto the road shoulder. The driver attempted to extinguish the fire with the fire extinguisher on the vehicle. Heat…

A CGH2 tube trailer-tractor was travelling to deliver hydrogen to a customer, when a fire developed on right side of the tractor around the rear of the hood and passenger side door. Very quickly…

The trailer experienced a tire/wheel fire at the rear of the tube trailer. The fire deteriorated the hand valve packing on one of the tube causing a slow leak of hydrogen. The trailer consisted of…

A tube trailer was driving on a highway, when the drivers noticed in the back camera smoke coming from the rear of the vehicle. After stopping the vehicle on the shoulder, they discovered a fire…

A fire started on the brakes of a truck carrying hydrogen. Due to the risk of extension of the fire to the hydrogen, the fire brigade install an emergency area until the fire is extinguished. There…

A tube trailer was returning to base after delivery of gaseous hydrogen. It went off road shearing off rear valves and manifolds and released 2000 cu ft of hydrogen [Zalosh and Short, 1978]

The HRS canopy was lower than the forecourt canopy. Heavy duty vehicles (HDV) were not noticing the issue and hitting the HRS canopy assuming same height. The canopy has now been repaired twice, and…

An empty fuel cells and hydrogen bus out of service was returning to the refuelling station, when it collided with a low bridge. This resulted in the rooftop hydrogen tanks being sheared off. The…

[Note HIAD validator: this an incident where a hydrogen system was affected, as effect of the initiating event, overpressure of LH2 tank with helium, but it is not a LH2 incident]. The second…

This event with minor hydrogen releases occurred during the operation of a hydrogen compressor. The compressor was part of a mobile hydrogen production unit and connected to a bundle of cylinders…

A hydrogen leak was detected in the dispenser pump causing the alarm to sound.
During a filling at a hydrogen refuelling station, the station was shut down due to a gas detection. The leak was extremely small and difficult to locate but the gas was directed upwards towards the…
The safety cabinet with compressed hydrogen was located in a laboratory and used to supply hydrogen to an experimental facility. The safety cabinet was equipped with exhaust extraction. Due to a leak…

A stainless steel manifold ruptured during experimental operation. The manifold was made of stainless steel and had a diameter of three inch (7. 5 cm). The hardware was off-the-shelf, slightly…

During the pump operation of a liquid hydrogen tanker, the vent valve was opened rapidly and the hydrogen detonated above the vent stack. The rapid valve opening was aimed at initiating a good…

A mixture of hydrogen and diesel leaked and ignited on a desulphurisation unit of a refinery. The emergency plan was initiated few minutes later. The unit was shut down and the leak was stopped.…

This entry refer to a series of events occurred before the date given, which corresponds to the publication of the evidences at the Int. Conference on Hydrogen Safety 2015. The nozzle/receptacle…