HIAD Facility - Operational Condition: Normal


A hydrogen leak occurred on a flange located on a pipe coming from the hydrogen storage tank. The staff was confined and the Internal Operation Plan was launched. Helium was injected in the tank and…
A small release of hydrogen occurred after the collision between a truck containing liquid hydrogen and a truck containing manganese dioxide on a highway. Due to the release, the traffic was…

The release occurred at a composite pressure vessel on the roof of a refuelling station (in the form of a ISO-container). The leak occurred on a treated connection to the vessel. The vessel…

A leak occurred on the safety valve of a train wagon transporting liquid hydrogen. The train was composed of 10 wagons. The train was stopped on the railway several hours to allow depressurisation of…
a hydrogen recycle compressor shut down unexpectedly, resulting in flaring activity with visible smoke.
A leak occurred on a rack containing 12 cylinders of hydrogen (50 l at 200 bar each) delivered by a lorry inside the fenced storage area of a bulb manufacturing plant. The plant’s safety manager…
A road tanker was being loaded with liquid hydrogen from a 15,000 gallon storage tank, when fire broke out after 1 inch rupture disc failed, ignition source was a loose connection in down stream…
The vent occurred at a hydrogen refuelling station (HRS) of a research laboratory (not public) serving heavy- and light-duty vehicle. The affected dispenser was a 700-bar dispenser for light-duty use…
A hydrogen leak alarm was received in the control room from the reformer of the hydrogen plant of a chemicals manufacturing facility. The reformed was depressurised and the leak stopped. The leak was…
An aerosol of hydrogen, hydrogen chloride and sulphuric acid is released in a plant producing chlorine via electrolysis. The exhaust pipe on the water circuit of the electrolyser was blinded due to…
A release of hydrogen took place in a metal cold rolling workshop. The hydrogen leaked from a cylinder of 15 m3, which was part of a storage system of 250 m3. Half of the workshop and the surrounding…
A hydrogen release occurred in a storage area of a nuclear power plant. . The storage consisted of three trailers made of 14 compressed gas cylinders each. The cylinders, mounted horizontally, had a…
In a plant manufacturing chlorate products, a hydrogen leak occurred via the water drainage outlet onto the factory floor. Pressure in the hydrogen line increased because the hydrogen pipes were…
Following the breakdown of a piston rod, a mixture of hydrogen and light hydrocarbons was released from the fresh hydrogen compressor of an oil refinery. The rod broke down because of stress…
A hydrogen safety sensor went into alarm at a hydrogen demonstration facility. The early morning temperature was near freezing and there was a trace of precipitation on exposed surfaces. Upon further…
A hydrogen leak occurred on one of the cylinders carried by a truck. After the leak was stopped, the vehicle was escorted by the fire brigade and taken to a laboratory for inspection. [Nore of the…
The event was initiated by the burst of a rupture disc on a reactor during a hydrogenation process. The hydrogenation reaction occurs under pressure in a tank containing 3,000 l of a mixture of…
A leak of a flammable mixture of hydrocarbons and hydrogen from a ruptured pipeline caused an explosion and fire, killing one person and injuring forty six. Investigations into the incident found…
A hydrogen leak occurs in a manufacture of steel pipes. The leak is detected and the alarm is triggered.
A temperature probe on a hydrogen make up gas compressor blew out from its compression fitting. This resulted in a release of hydrogen. The incident occurred due to a fatigue failure of the…